Skipping dynamic balancing after a repair saves the workshop time and labour, but the plant pays for it: residual imbalance drives high vibration, early bearing failure, shaft deflection, rotor cracking, higher energy use and unplanned downtime. The cheapest place to remove imbalance is on a balancing machine in the workshop,
Read More
A cooling tower gearbox motor unit overhaul follows seven steps: condition assessment, safe dismantling, cleaning and component inspection, repair or replacement, oil change and lubrication, reassembly with precision alignment, and testing before return to service. Done in that order, it catches bearing wear, oil contamination, misalignment and gear damage before
Read More
Generator overhauling belongs in a specialised facility because an alternator is several interconnected systems, not one winding. The main stator, rotor, exciter, AVR and rectifier must be diagnosed, repaired and tested together, which takes a test bench, a burn-off oven, varnish immersion, dynamic balancing and cranes that can lift the
Read More
Electric motors form the foundation of almost all industrial operations. They are the ones that provide power to pumps, compressors, conveyors, fans, and a great number of other processes. However, the truth is that the majority of motor failures do not occur overnight. Most of the time, they are a